How Fuel Smart HydroStat saves fuel

Fuel Savings through Boiler Reset (See video)

Boiler Reset is the decades-old principle of governing boiler temperature in accordance with the heating demand.  A boiler is sized to heat a home during the coldest days of the year.  During all other times, the heating system is larger than it needs to be.  Boiler Reset saves fuel by reducing the boiler temperature during periods of non-peak demand.  The FuelSmart Hydrostat offers two cost effective ways to provide this fuel saving technology:

Thermal Targeting ™ – This on-board microprocessor based algorithm monitors thermostat activity and continually evaluates how much heat the house requires.  When it is very cold outside, the demand for heat is high and the Fuel Smart HydroStat raises the boiler’s Target Temperature to provide needed heat to the house.  When the outside temperature is milder, the demand for heat is lower.  During these periods, the Fuel Smart HydroStat lowers the boiler’s Target Temperature- saving fuel- while continuing to provide comfort to the house.

Outdoor Reset & Warm Weather Shutdown – For those who prefer the more traditional outdoor reset approach, Hydrolevel offers a low cost OS-100 Outdoor Sensor Kit (sold separately).  When the sensor is plugged into the control, the boiler reset methodology changes instantly from Thermal Targeting to Outdoor Reset, where the boiler temperature is governed by the temperature outside.  The addition of the sensor also allows the control’s Warm Weather Shutdown feature to be activated.  This feature prevents the boiler from supplying space heating when the outside temperature exceeds a selected level.

 

Optional Features

Easily activated in HydroStat’s program mode

 

Thermal Pre-Purge ? Further enhances boiler efficiency by supplying latent heat, that may remain in the boiler from a previous run cycle, to the heating zone requiring heat. The control activates the burner only when it determines that the latent heat will not be adequate to satisfy the heating demand.  During the Pre-Purge cycle, the display will indicate Pur.

Degrees Celsius ? Changes the control’s settings to display Celsius.

Manual Reset LWCO ? Changes the low water cut-off function to manual reset, which is required for many commercial installations.

Circulator Activation ? Can be set to activate the primary circulator on calls from t/t, ZC/ZR, or both.

Enhanced Condensing Protection ? To reduce the potential for condensing, on a call for heat, this feature allows the boiler to heat to 125°F prior to energizing the circulator. Once activated, the control continues to monitor boiler temperature and interrupts the circulator if it drops below 115°F.

 

Accessories & Remote Mounting Options

For all HydroStat Models except 3000 Series

Wall/Jacket Mounting Kit Wall/Jacket Mounting Kit

Wall/Jacket Mounting Kit
Kit includes: 2 mounting brackets, remote sensor, plastic grommet, rubber well cap, 4 #8×1/2″ self-tapping screws.

48-101 HydroStat Wall/Jacket Mounting Kit with 2′ sensor
48-102 HydroStat Wall/Jacket Mounting Kit with 4′ sensor
48-103 HydroStat Wall/Jacket Mounting Kit with 10′ sensor

 

Pipe Mounting Kit Pipe Mounting Kit

Pipe Mounting Kit
Kit includes: mounting bracket for 1″ to 2″ pipe, remote sensor, plastic grommet, rubber well cap.

48-121 HydroStat Pipe Mounting Kit with 4′ sensor

Filed Under: Latest

Fuel Smart HydroStat Video

Fuel Smart HydroStat Video

Filed Under: Latest

Fuel Smart HydroStat 3200-Plus/3250-Plus

Fuel Smart HydroStat Models 3200-Plus and 3250-Plus

  

 

Model 3200-Plus |  Model 3250-Plus

fuel-smart-hydrostat

3200 Installation Manual
Temperature Limit
Designed for cold start and tankless coil boilers
3250 Installation Manual
Low Water Cut-Off
Provides protection against potentially dangerous low water conditions when installed with the Hydrolevel Electro-Well™
Sales Sheet

Boiler Reset
  • Thermal Targeting – On-board microprocessor saves fuel by adjusting boiler temperature based on heating demand
  • Outdoor Reset Ready – Provides outdoor reset and warm weather shutdown with addition of Outdoor Sensor Kit

The Fuel Smart HydroStat is standard equipment on many premier boiler lines.  It can also be used as a universal replacement control to improve the performance and fuel efficiency of older boilers. See our Sales Sheet for more information. 

» Click here to learn how Fuel Smart HydroStat saves fuel.

» Click here to read more about the Hydrostat’s optional features.

Accessories:

  • Electro-Well (needed to activate Low Water Cut-Off functionality)
  • Outdoor Sensor Kit
  • Remote Mounting Kit
Specifications Model 3250-Plus Model 3200-Plus Model 3000

Burner Contacts

7.4 FLA, 44.4 LRA@120 VAC

30VA@120VAC

50VA@24VAC

 

Circulator Contacts

5.8 FLA, 34.8 LRA@120VAC

5.8 FLA, 34.8 LRA@120VAC

  
Operating Range – Low Limit OFF or 110°F-200°F OFF or 110°F-200°F OFF or 110°F-200°F 
Operating Range – High Limit 100°F-220°F 100°F-220°F 100°F-220°F 
Differentials Automatic 10-20 Automatic 10-20   

 MODEL  VOLTAGE DESCRIPTION/OPERATION
3250 Plus 120 VAC, 60HZ For oil boilers. Cold Start or Warm Start operation. Thermal Targeting feature factory set to off position. Activation of Thermal Targeting feature will adjust boiler water temperature according to changes in heat load, or use OS-100 Outdoor Sensor Kit to automatically activate outdoor reset and warm weather shut-down functionality. IMPORTANT: LWCO functionality automatically activated when installed on Electro-Well.

Replaces: Honeywell L7124, L7124C, L7148A, L7224A, L7224C, L7224U. L7248C, L8124A, L8124C, L8148A, L8148C

3200 Plus 120 VAC, 60HZ

24VAC Output

For gas boilers. Cold Start or Warm Start operation. Thermal Targeting feature factory set to off position. Activation of Thermal Targeting feature will adjust boiler water temperature according to changes in heat load, or use OS-100 Outdoor Sensor Kit to automatically activate outdoor reset and warm weather shut-down functionality. IMPORTANT: LWCO functionality automatically activated when installed on Electro-Well

Replaces: Honeywell L8124E, L8148E

   
   
   
3000 24 VAC For cold start gas boilers, universal replacement high limit control with adjustable high limit.  Replaces smaller, single function limit control models.

Replaces Honeywell L4006A, L4080B

See Model 3000 Details

   
   
   
   View Fuel Smart Hydrostat Video                                                                      

*Aquastat is a registered trademark of Honeywell

Filed Under: Home, Home-bottom-1, Hydrostat, Hydrostat, Latest, Products

Fuel Smart HydroStat – Limit, LWCO w/Boiler Reset

HydroStat
HydroStat

Fuel Smart HydroStat Temperature Limit, LWCO & Boiler Reset Control

Temperature Limit and Low Water Cut-Off with Boiler Temperature Reset – for Oil & Gas Fired Boilers

Temperature Limit
Universal replacement for common Aquastat* models

  • Provides cold start and tankless-coil operation
  • Easy to Set, dial type limit settings
  • Industry standard wiring designations

Boiler Reset
Lowers the boiler temperature to save fuel without sacrificing comfort

  • Easy to Install – No outdoor sensor required
  • Easy to Set – Just dial in the number of heating zones
  • Works with virtually any boiler


How It Works

Low Water Cut-Off
Protects boilers from damaging low water conditions

  • Easy to install – No outdoor sensor required
  • Easy to set – Just dial in the number of heating zones

Specifications Model 3250 Model 3200
Burner Contacts 7.4 FLA, 44.4 LRA@120 VAC 30VA@120VAC
Circulator Contacts 5.8 FLA, 34.8 LRA@120VAC 5.8 FLA, 34.8 LRA@120VAC
Operating Range – Low Limit OFF or 110°F-200°F OFF or 110°F-200°F
Operating Range – High Limit 100°F-220°F 100°F-220°F
Economy Settings OFF, LO, 1,2,3,4,5,HI OFF, LO, 1,2,3,4,5,HI
Differentials Automatic 10?-20? Automatic 10?-20?

 MODEL  VOLTAGE DESCRIPTION/OPERATION
3250 120 VAC, 60HZ For oil boilers. Cold Start or Warm Start operation. Thermal Targeting feature factory set to off position. Activation of Thermal Targeting feature will adjust boiler water temperature according to changes in heat load. IMPORTANT: Provides only temperature and reset functionality when installed on existing standard immersion well. LWCO functionality automatically activated when installed on ElectroWell (TM)

Replaces: Honeywell L7124, L7124C, L7148A, L7224A, L7224C, L7224U. L7248C, L8124A, L8124C, L8148A, L8148C

   
   
   
 
3200

120 VAC, 60HZ

24VAC Output

For gas boilers. Cold Start or Warm Start operation. Thermal Targeting feature factory set to off position. Activation of Thermal Targeting feature will adjust boiler water temperature according to changes in heat load. IMPORTANT: Provides only temperature and reset functionality when installed on existing standard immersion well. LWCO functionality automatically activated when installed on ElectroWell (TM)

Replaces: Honeywell L8124E, L8148E

   
   
   

 
 
 
 
*Aquastat is a registered trademark of Honeywell
 

 

Filed Under: Latest, Products

Pump Contoller & LWCO

pump 250

 

 

  • No Moving Parts in Boiler Water
  • Controls Boiler Feed Pump
  • Available with Water Column Type Body
  • Accommodates Boilers to 250 PSI
Installation Manual

Specifications Models 250
Primary Relay 10 FLA, 60 LRA
Pump Relay 20 FLA, 120 LRA
Switch Control DPST
Power Consumption 13 VA

MODEL  INCLUDES DESCRIPTION/OPERATION
PUMP CONTROL / CUT-OFF WITH AUTOMATIC RESET
250 Controller
Model 250C
Manifold
(3) EL1214
Probes

Operates boiler feed pump to maintain water level between middle and upper probes. Burner circuit contacts open if water drops below bottom probe. Automatically restarts burner on return of normal water level.

 

 

Same as Model 250 with water column body, tri-cock and gauge glass tappings.

250WC Controller
Model 1214C-1 Manifold
(3) EL1214
Probes
PUMP CONTROL / CUT-OFF WITH TIME DELAY & MANUAL RESET
LCFT-967 Controller
(for remote
mounting)
Model 1214 C-1
(3) EL1214
Probes
Operates boiler feed pump to maintain water level between middle and upper probes. If water drops below bottom probe, the burner circuit contacts open after a 60 second delay. Locks-out burner circuit if water remains below bottom probe for 90 seconds. Manual reset will not lock-out from power interruptions.

Filed Under: Latest, Products

  • 1
  • 2
  • 3
  • Next Page »

PRODUCTS

  • Fuel Smart HydroStat
  • HydroStat Temperature Limit & LWCO 3150
  • Fuel Smart HydroStat 3000
  • Low Water Cut-Offs – Water Boilers
  • Low Water Cut-Offs – Steam Boilers
  • Water Feeders – Steam Boilers
  • Tank Level Control
  • Pump Controller & LWCO
  • Flow Switches
  • Parts & Accessories

Product info, guides, support

  • Full Product Catalog
  • Sales Sheets
  • Installation Instructions
  • Specification Sheets
  • Competitive Cross Reference

Copyright © 2018 ·HYDROLEVEL COMPANY | 126 Bailey Road, North Haven, CT 06473 | Ph. (203) 776-0473 | Fax: (203) 764-1711 | info@hydrolevel.com